4.3 SLJ Valve Mixing Block Rebuilding:
Valves should be rebuilt if they are leaking. Cornelius supplies all the parts necessary for
rebuilding.
1. Loosen cam lock-washer on
both water lines.
2. Remove two screws on the
bottom of the plate.
Loosen cam
lock-washer
cam lock-
washers
Screws