Cornelius 500-Series Spécifications

Naviguer en ligne ou télécharger Spécifications pour Les fabricants de glaçons Cornelius 500-Series. Cornelius 500-Series Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Owner / Operator Manual
IMI Cornelius Inc.
Corporate Headquarters
One Cornelius Place
Anoka, MN 55303–6234
U.S.A.
Release Date: December 7, 2001
Revision Date: March 18, 2002
Publication Number: 630460146
Revision: F
www.cornelius.com
IMPORTANT:
TO THE INSTALLER.
It is the responsibility of
the Installer to ensure that
the water supply to the
dispensing equipment is
provided with protection
against backflow by an air
gap as defined in
ANSI/ASME A112.1.2-1979;
or an approved vacuum
breaker or other such
method as proved effective
by test.
Water pipe connections
and fixtures directly
connected to a potable
water supply shall be
sized, installed, and
maintained according to
Federal, State, and Local
Codes.
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or
operating this equipment
Commercial Refrigeration Service, Inc.
WWW.IceCubes.NET
(866) 423-6253
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Owner / Operator Manual

Owner / Operator ManualIMI Cornelius Inc.Corporate HeadquartersOne Cornelius PlaceAnoka, MN 55303–6234U.S.A.Release Date: December 7, 2001Revision Da

Page 2

6304601466March 18, 2002DISPENSER INSTALLATION1. The proper cuber/dispenser installation package should be ordered. This package will include gasket m

Page 3

6304601467March 18, 2002ELECTRICAL1. All wiring and connections must conform to national and local electrical codes.2. Wire size and circuit protectio

Page 4

6304601468March 18, 2002OPERATIONUNIT SELECTION1. The unit selection dip switches tell the microprocessor the correct water level difference for harve

Page 5 - MODEL AND SERIAL LOCATION

6304601469March 18, 2002START UP SEQUENCE (PRIMARY)1. Check all connections.2. Turn on the main power switch, the red LED will flash (6) times, then b

Page 6 - SPECIFICATIONS

63046014610March 18, 2002FREEZE CYCLE1. Ten seconds after the fill valve turns off, the microprocessor records the water level.2. Using the recorded h

Page 7 - NA= Not applicable

63046014611March 18, 2002TOTAL ICE CAPACITYIce capacity of any ice maker is affected by many operating conditions, such as water and air temperature a

Page 8 - TECHNICAL SPECIFICATIONS

63046014612March 18, 2002FLASHING CODE FOR SELF DIAGNOSTICS (1400’s and 1800’s)Delay LED Error LED1 High Condenser Temperature Delay 1 High Condenser

Page 9 - INSTALLATION INSTRUCTIONS

63046014613March 18, 2002HARVEST BUTTONManual Harvest1. At any time after secondary start up, the machine can be put into the harvest cycle by depress

Page 10 - PLUMBING CONNECTIONS

63046014614March 18, 2002MAINTENANCESEMI-ANNUAL MAINTENANCE1. GENERAL ICE MACHINE INSPECTION2. CLEANING THE EXTERIOR3. CLEANING THE CONDENSER –AIR-COO

Page 11 - START UP SEQUENCE

63046014615March 18, 20021. Clean the outside of the condenser with a soft brush or vacuum with a brush attachment. Brush or washcondenser from top to

Page 12 - OPERATION

Distributed By:Commercial Refrigeration Service, Inc.WWW.Cornelius Parts.COMWWW.IceCubes.NET(866) 423-6253(623) 869-8881

Page 13 - March 18, 2002

63046014616March 18, 20024. Remove the water tube, clean with brush and “Calgon Nickel Safe” ice machine cleaner.SCALE 1:2INNER WATER DISTRIBUTORINNER

Page 14

63046014617March 18, 2002

Page 15 - 1000’s, and 1200’s)

63046014618March 18, 2002

Page 16 - Harvest Mode

63046014619March 18, 2002BEFORE CALLING FOR SERVICEIf a problem arises during the operation of your ice machine, follow the checklist below before cal

Page 17 - CLEAN CYCLE

63046014620March 18, 2002WARRANTYIMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and work-manship under nor

Page 18 - SEMI-ANNUAL MAINTENANCE

63046014621March 18, 2002THIS PAGE LEFT BLANK INTENTIONALLY

Page 19 - CLEANING THE INTERIOR

63046014622March 18, 2002IMI CORNELIUS INC.CORPORATE HEADQUARTERS:One Cornelius PlaceAnoka, Minnesota 55303-6234(763) 421-6120(800) 238-3600

Page 20

Model and Serial Location 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Xtreme Ice Machine 1. . . . . . . . . . . . . . . . . . .

Page 21

Cleaning the Interior 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning Procedure if there is

Page 22

6304601461March 18, 2002MODEL AND SERIAL LOCATIONXTREME ICE MACHINECondenser Discharge AirDeflector (as required)*Bin Adapter (as required)*Model/Seri

Page 23 - BEFORE CALLING FOR SERVICE

6304601462March 18, 2002SPECIFICATIONSThe following table contains equipment specification information for the Ice Machines.ModelXAC322/330XWC322/330X

Page 24 - WARRANTY

6304601463March 18, 2002ModelXAC1444XWC1444XRC1444XAC1844XWC1844XRC1844XAC322E50XAC 330E50XAC 522E50XAC 530E50UNITVoltsPhaseHertzNo. Wires2301602+Grou

Page 25

6304601464March 18, 2002GENERALFREIGHT DAMAGE CLAIMS PROCEDUREThe deliverer of your equipment (freight company, distributor or dealer) is responsible

Page 26 - (800) 238-3600

6304601465March 18, 2002INSTALLATION INSTRUCTIONSInstallation and start-up of the equipment should be performed by the distributor or the dealer’s pro

Commentaires sur ces manuels