4.2 SLJ Rinse/Flush Valve Rebuilding:
Valves should be rebuilt if they are leaking. Cornelius supplies a kit which includes all the
O-rings (p/n 45026100).
1. See Installation And Service Manual for pump platform removal procedure.
2. Remove four screws and lift valve
assembly up, disconnect wires in the
back of the valve.
3. Remove two screws holding the
valve to the bracket.
4. Loosen screw that holds cam-lock
washer and disconnect the syrup line.
Valve
Assembly
Screws
Syrup
Line
Port
Fastening
Screw &
Cam-lock
Washer