SAFETY CONTROLS
Your Icemaker unit has several safety and control devices incorporated into its design.
WARNING: None of the below described devices should ever be ”bypassed” to allow the
unit to function.
The safety and control system shut–off devices are:
FIGURE 13. GEAR MOTOR OVERLOAD
1. Low water shut off reed switch located in icemaker float assembly. (Automatic reset type).
2. Gear motor thermal overload, manual reset type (red button on motor). See Figure 12.
3. Compressor thermal overload, automatic reset type.
4. Main service switch located on top of the control box.
5. Hopper shut–off.
6. High pressure cut out (water cooled only).
WARNING: Do not reset gear motor overload if ice is present in the evaporator.