18
638085277
2. Remove motor end bell and stator, if necessary.
3. Check terminals 1 and 3 on overload. No continuity replace overload. Use a volt–ohm meter. See Figures
10 and NO TAG
NOTE: Gear motor and related components can be checked from Pin Connector. See Figures 10 and
NO TAG.
MOTOR CHECK:
The resistance readings on the windings will be between 5 to 25 ohms. A meter capable of these low readings
must be used. The Start Relay cover must be removed.
If no continuity on start or run winding test, replace stator. If continuity on grounded motor test, replace stator.