Cornelius SID650W/80-BC Manuel de l'opérateur Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
29 91704
YES
4. BEVERAGE SYSTEM PROBLEM
NO
IS
ONE OR MORE
FAUCETS
INOPERATIVE?
1. CHECK WIRING CONNECTIONS TO IN-
OPERATIVE FAUCETS.
2. REPLACE INOPERATIVE FAUCETS.
3. CHECK WIRING CONNECTIONS FROM
24V. TRANSFORMER.
4. CHECK 24V. TRANSFORMER.
IS
BEVERAGE
COLD?
IS
BEVERAGE
PROPERLY
CARBONATED?
IS
BEVERAGE
TOO SWEET?
IS
BEVERAGE
TOO WATERY?
DONE
1. CHECK REMOTE COOLING
SYSTEM. (-B MODELS)
2. CHECK FOR ICE ON COLD
PLATE. (-BC MODELS)
3. CHECK CO
2
PRESSURE.
4. CHECK CARBONATOR.
1. CHECK WATER SUPPLY PRESSURE.
2. CHECK SUPPLY FILTER.
3. CHECK CARBONATOR.
4. CHECK FAUCET BRIX.
1. CHECK IF SYRUP TANK IS EMPTY.
2. CHECK CO
2
PRESSURE.
3. CHECK FAUCET BRIX.
NO
NO
NO
NO
YES
YES
YES
YES
Vue de la page 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Commentaires sur ces manuels

Pas de commentaire