32
90846
3. DISPENSER PROBLEM
DOES
AGITATOR
ROTATE?
DOES
GATE OPEN?
IS
VOLTAGE AT
SOLENOID
103-126V.?
YES
YES
YES
NO
1. CHECK MOTOR CAPACITOR.
2. CHECK TIMER SWITCH #5!
3. CHECK AGITATOR MOTOR.
1. CHECK FOR BURNED OUT SOLE-
NOID.
2. CHECK FOR STUCK OR BINDING
GATE MECHANISM.
IS
HOPPER LEVEL
TOO HIGH
1. CHECK FOR BLOWN SOLENOID FUSE IN ELECTRIC BOX.
IF FUSE IS BLOWN CHECK FOR STUCK GATE MECHANISM
BURNED OUT SOLENOID, OR LOW VOLTAGE.
2. CHECK VEND SWITCH
3. CHECK FOR LOOSE OR BROKEN WIRE CONNECTION IN
SOLENOID CIRCUIT.
4. CHECK VOLTAGE PROBLEM IN 1.
NO
NO
1. CHECK BIN THERMOSTAT
ADJUSTMENT.
2. REPLACE BIN THERMOSTAT.
IS
ICE SLUSHY?
NO
YES
1. CHECK HOPPER DRAINS.
2. CHECK LEVEL OF UNIT.
3. CHECK FOR WATER OVERFLOW FROM
EVAPORATOR. SEE SECTION 2.
4. CHECK ADJUSTMENT OF TIMER CAM #5.
(AGITATION)
5. CHECK TIMER SWITCH #5.
YES
DONE
NO