Cornelius SID650A/80-B Manuel de l'opérateur Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 41
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
28
90846
YES
NO
2.D FROZEN EVAPORATOR
IS
AMBIENT ABOVE
60°F?
IS
VOLTAGE WITHIN
±10%?
CHECK VOLTAGE ITEMS IN 1.
DISCONNECT PROBE WIRE FROM
CONDUCTIVITY CONTROL.
ARE ALL
TIMING FUNCTIONS
ACCURATE TO SETTINGS
±10%?
HOT
GAS OPERATION
O.K.?
WATER
DUMP
O.K.?
DOES
ICE HARVEST
NORMALLY?
YES
NO
NO
YES
YES
YES
YES
NO
NO
NO
1. ARRANGE TO MAINTAIN MINIMUM
60° AMBIENT.
2. CONDUCT FACTORY REGARDING
SPECIAL APPLICATION.
1. CHECK TIMER MOTOR.
2. CHECK CONDUCTIVITY CONTROL.
1. CHECK ADJUSTMENT OF TIMER
CAM #2. (HOT GAS)
2. CHECK TIMER SWITCH #2.
3. CHECK HOT GAS SOLENOID.
1. CHECK ADJUSTMENT OF
TIMER CAM #4 (WATER DUMP)
2. CHECK TIMER SWITCH #4
3. CHECK DUMP SOLENOID
1. SHUTOFF ICE MAKER AND THAW EVAPORATOR.
2. START ICE MAKER.