Printed in U.S.A.Liquid Base Beverage DispenserINSTALLATION & OPERATORS MANUALTHIS DOCUMENT CONTAINS IMPORTANT INFORMATIONThis Installation Manual
8630460001Figure 1Cancel/PourSwitchLED IndicatorLightNote: Check local specifications for dispensed product water to syrup ratio specifications.G. If
9630460001SANITIZING THE SYSTEM (USA)IMPORTANT: Only trained personnel should perform sanitizing procedures.WARNING: Wear protective eyewear to avoi
1063046000115. Remove the tube-end connectors from the detergent.16. Dispose of unused detergent in a sanitary sewer, not in a storm drain. Wash the c
TABLE OF CONTENTSGENERAL DESCRIPTION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1630460001GENERAL DESCRIPTIONUNIT DESCRIPTIONThe Three-Flavor Tower is compact and may be island-mounted or installed on a front or rear counter. TheT
2630460001UNPACKING AND INSPECTIONCAUTION: Unit must be lifted by the S/S tower to avoid damage. Do Not lift using valvehousings.Unpack a Unit as fol
3630460001COUNTERTOP HOLE LOCATION (TUBING ACCESS)1. Using the template provided, layout the location of the access hole.2. Cut the access hole in the
46304600017. Check all connections for leaks before insulating the tubing.Python InsulationCold Carbonated WaterFrom Cooling UnitCold Carbonated Water
56304600012. Carefully tilt the connected Unit up to expose the base.3. Apply a silastic sealant e.g. Dow Corning RTV 731 or equivalent on all base ed
6630460001POTABLE WATERSOURCE STRAINER WATER PRESSUREREGULATORPRIMARY REGULATOR70-80 PSICHECK VALVECO2 CYLINDERBAG-IN-BOX (3)CONCENTRATEPLAIN WATERCO2
7630460001Connect concentrate tubing to concentrate SourcesConnect concentrate tubing to concentrate sources for bag-in-box (or tank).Make Electrical