C
Triton
Please keep these operating instructions in a safe place.
Dear Customer:
Check this product for visible damage immediately upon receipt. Inform the shipper if there is any shipping damage.
Note that damage resulting from improper handling or operation is not covered under the warranty.
Before putting the device into operation:
Read all the operating instructions carefully.
Familiarize yourself with all controls.
Ask the service company installing the device to write its address down here for any subsequent repairs, emergencies,
etc.
Address of your technical service company: Name: ................................
City: ................................
Street address: ................................
Telephone: ................................
Contact person: ................................
Table of Contents
Page
1. Introduction ......................................................................................15
2. Safety Regulations ............................................................................16
3. Installation Site Requirements .......................................................... 16
4. Installation........................................................................................17
5. Putting into and out of Service .........................................................18
6. Instructions for Cleaning ..................................................................19
7. Problems and Troubleshooting.........................................................20
8. Technical Data ..................................................................................21
9. Illustration ........................................................................................ 22
10. Flow Chart and Circuit Diagram ..................................................... 23
11. Adjusting of the ice-bank-probe........................................................ 25
12. Installation Check List...................................................................... 26
1. Introduction
Our foremost aim is to produce a quality product. If you should encounter any difficulty which these operating
instructions do not help you with, call or write us. We will be glad to be of assistance. If you write, please include the
model and serial number of the device.
Our address: IMI Cornelius Deutschland GmbH
Carl-Leverkus-Strasse 15
D-40764 Langenfeld, Germany
Tel. 0(xx49) 2173 793-0
Fax: 0(2173) 2173 77438
Vue de la page 0
1 2 3 4 5 6 ... 12 13

Résumé du contenu

Page 1

Page 15C TritonPlease keep these operating instructions in a safe place.Dear Customer:Check this product for visible damage immediately upon receipt.

Page 2

Page 24C Triton10.4 Flow Chart of Triton 250010.3 Flow Chart of Triton 700

Page 3

Page 25C Triton10.5 Circuit diagram of Triton 15010.6 Circuit diagram of Triton 350 and 700

Page 4

Page 26C Triton10.7 Circuit diagram of Triton 250011. Adjusting of the ice-bank-probeThe dimension is critical for the adjustment.The icebank probe ad

Page 5

Page 27C Triton12. Installation Check ListYou can use this check list to review the installation of the device. Fill out the check list and keep it wi

Page 6

Page 16C Triton2. Safety Regulations2.1 General Safety RegulationsThis device is of leading-edge design and manufacture. If used and maintained in acc

Page 7 - (3/4) (1)

Page 17C Triton3.2 Electrical ConnectionsA socket outlet with an earthing contact featuring a maximum protection of 16 amps is required.The line volt

Page 8

Page 18C TritonClean the couplings on the container for beverage / syrup every time before you attach them. Connect coupling tocontainer for beverage

Page 9 - 10.1 Flow Chart of Triton 150

Page 19C Triton5.4 Daily InspectionCheck whether carbon dioxide and water lines are open. Working with closed water feed lines results in draining oft

Page 10 - 10.3 Flow Chart of Triton 700

Page 20C Triton7. Problems and TroubleshootingBefore looking for problems with the dispensing equipment, first check:Is the flow of electricity to the

Page 11

Page 21C Triton8. Technical DatasTriton 150 Triton 350 Triton 700 Triton 2500Output capacity at atap rate of 4 drinksof 0.3 L each per minute 130 340

Page 12

Page 22C Triton9. Illustration of the TritonTriton 350, Triton 700 Triton 2500 (for example Triton 350)Triton 1509.1.4 Triton 25009.1.3 Triton 700

Page 13

Page 23C Triton10.2 Flow Chart of Triton 35010.1 Flow Chart of Triton 15010. Flow Chart and Circuit diagram