Cornelius SID851A/250S-BC Manuel de l'opérateur Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
25 90914
YES
NO
2.D (CONTD)
1. CHECK ADJUSTMENT OF TIMER CAM
#3. (HARVEST MOTOR)
2. CHECK TIMER SWITCH #3.
3. CHECK HARVEST MOTOR CAPACITOR.
4. CHECK HARVEST MOTOR.
REPLACE PROBE WIRE ON
CONDUCTIVITY CONTROL
DURING HARVEST CYCLE.
DOES
TIMER RETURN
HOME?
WAIT ONE FULL FREEZING
CYCLE (APPROX. 6-10 MIN.)
1. CHECK ADJUSTMENT OF TIMER
CAM #1. (TIMER HOME)
2. CHECK TIMER SWITCH #1.
DOES
HARVEST
INITIATE?
1. CHECK PROBE WIRING FOR
SHORTED CONNECTION.
2. CHECK CONDUCTIVITY CONTROL.
DOES
ICE HARVEST
NORMALLY?
1. REPEAT PREVIOUS CHECK OF OPERATION OF HARVEST
COMPONENTS IN 2.D.
2. ADJUST ICE THICKNESS PROBE ONLY AFTER ALL OTH-
ER FACTORS HAVE BEEN CHECKED THOROUGHLY.
DONE
YES
YES
YES
NO
NO
NO
Vue de la page 27