Countertop Icemaker IMD Series Installation Manual
Publication Number: 638085277INS - 8 - © 2004-2009, IMI Cornelius Inc.
SEMI-ANNUALLY
Semi-Annually in addition to all previously established service procedures perform the following:
1. Check for water leaks in tube connections, water fittings, and lower icemaker water seal.
2. Check drain tubes for clogs and “aged” tubes. Replace if tubes are stained or brittle.
3. Check for signs of condensation. Clean where necessary and replace insulation properly.
4. Check safety circuits for proper operation.
5. Check refrigeration system.
6. Check unit for abnormal noise. Tighten machine and cabinet screws, if necessary.
7. Check white upper bearings on auger assembly. If bearings are less than 1/16” thick, replace. See
FIGURE 5.
FIGURE 5. UPPER BEARING AND AUGER ASSEMBLY
NOTE: Preventive maintenance can increase the trouble-free life of your icemaker. Failure to
perform preventive maintenance could void your equipment warranty.
REPLACE