Cornelius 500-Series Manuel de service Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
13 TD 184
THE FOLLOWING MAINTENANCE SHOULD
BE PERFORMED AT LEAST EVERY SIX
MONTHS ON FLAKED ICE MACHINES
1. Check power supply with machine running for prop-
er voltage.
2. Check water level in the float tank reservoir. Water
level should be maintained at the top of the evapo-
rator. Adjust if necessary.
3. Clean the air-cooled condenser coil with a stiff
brush or vacuum cleaner.
CAUTION: CONDENSER COOLING FINS ARE
SHARP, USE CARE WHEN CLEANING.
4. Clean the ice storage bin and flush the bin drain at
least once a month.
5. If a water conditioner is installed in the inlet water
line, change, replace or clean the filter, strainer or
cartridge as required.
6. If heavy mineral deposits on the auger and evapo-
rator shell are encountered due to bad local water
conditions, follow sanitizing and cleaning proce-
dure.
7. Loosen holddown cam locks and remove gear
motor assembly.
8. Check thrust washer; replace if noticeably worn.
9. Lift out auger and examine for wear. If the Helix
auger or the corkscrew auger round bar becomes
flat on the inside more than 1/8 of an inch over a
length of two inches or more it should be replaced.
NOTE: HELIX AUGERS DO HAVE MACHINED
FLAT RELIEF SURFACES. DONT CONFUSE
THEM WITH WORN FLAT AREAS.
Check the insert in the bottom ring of the Helix au-
ger and replace if excessively worn.
10. Check shell vertical strips for wear. Replace the
shell if excessive wear shown.
11. Check O-ring, replace if worn or cut.
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 34 35

Commentaires sur ces manuels

Pas de commentaire